How to uninstall the indoor monitor to connect the Connectivity module?

1. Unhook the indoor monitor from its mounting wall by pulling it upwards.

2. Leave the mounting wall in place.

3. Memorize or take a photo of the connection on the back of the monitor, in order to locate the power cables (DC 24V terminal block) and the outdoor panel (CS/Call station terminal block).

 

 

4. Without unscrewing the blue cable connectors , unplug all the connectors present to release the monitor.

 

If you have a second monitor, it is not compatible with the connectivity module. It will no longer be possible to answer to a visitor's call. However, you can continue to use it to control Somfy equipment via radio (RTS/io) and launch TaHoma® scenarios (VR500 PRO io monitor only).

 

5. Identify the 2 power wires connected to the DC 24V terminal block, noting the polarity (+ and -) and identify the 2 wires from the door panel connected to the CS/Call station terminal block. Polarity does not matter.

 

 

6. Use the screwdriver provided to unscrew the blue connectors from the identified cables. These will no longer be used.